P4 explains emergency lighting obligations

// fire, security and safety

Emergency Lighting is of the utmost importance and a legal requirement in premises, excluding domestic premises, across the UK. In England and Wales the Regulatory Reform (Fire Safety) Order 2005, usually referred to as the Regulatory Reform Order (RRO), brings very significant fines for breaches of the order (with or without a fire) and offenders are aggressively prosecuted. It is therefore vital that businesses, organisations and individuals are aware of the regulations and the obligations they impose.

Responsible Person
The responsibility for emergency lighting rests with a 'Responsible Person', who has control, or a degree of control, over premises and fire-safety systems within premises. In English law a ‘person' can be either an individual or an entity such as a limited company.
Therefore the ‘Responsible Person’ could be the building owner, landlord, facilities manager, estates manager, building occupier or designated person. They may all individually or collectively be responsible for the safety of everyone who might be on the premises at any time.
The ‘Responsible Person’ (or ‘Responsible Persons’) must ensure everyone on the premises, or nearby, can escape safely if there is a fire or failure of the mains power supply, and must provide appropriate assistance to those who may need extra help or have a disability.

Suitability and Compliance
Documentation must be available to enable the ‘Responsible Person’ to demonstrate the suitability and compliance of their system to inspecting authorities, who have the responsibility to enforce the Regulatory Reform Order. Inspecting authorities may investigate on a random basis, as a result of information, or if there has been fire or false alarm.
There is an emphasis on ‘consultation’, covered in Clause 4.1 of BS5266 Part 1: 2016. This stipulates that it is important, if possible, to consult with all relevant persons, so that the ‘Responsible Person’ can consider all of the hazards and people at risk, together with the capabilities of maintenance and operating staff to enable the design and installation to match the emergency lighting to the application needs.
As the legislation acts retrospectively, regular risk assessments are required to demonstrate compliance. Therefore, premises engineered to previous versions of the standards need to be assessed to consider if they need to be upgraded. The ‘Responsible Person’/Risk Assessor might require guidance to assist them to decide if an upgrade to the latest standard is needed, and also to identify the degree of the urgency

Risk Assessment
Employers and persons who have control of premises are required by legislation to carry out an assessment of the fire risks to occupants of premises and other people in the vicinity of the premises to ensure that they are protected from fire and its effects. The regulatory Reform (Fire Safety) Order 2005 requires that the risk assessment, which is referred to as the “Fire Risk Assessment” is suitable and sufficient.
The installed emergency lighting should be evaluated as part of the assessment of the means of escape within the “Fire Risk Assessment”. Persons carrying out this “Fire Risk Assessment” should be competent, having appropriate experience and/or qualification. The “Fire Risk Assessment” should be regularly reviewed (typically every 12 months) against the latest issue of BS5266 Part 1 to consider whether emergency lighting installations are adequate.
P4 Limited are specialists in self-testing emergency lighting solutions and have been supplying Fully Automatic Self Testing Emergency Lighting for nearly 30 years. Major healthcare, education, local authority, residential, commercial and industrial premises have relied on P4’s market leading systems to ensure building occupants are provided with the best escape lighting systems, to assist safe evacuation if an emergency situation should arise.
P4 continues to work with customer’s year in and year out, supporting them in the maintenance and compliance of their P4 installation and often extending installations into additional areas of their premises.

For further information or to discuss your emergency lighting requirements, please call P4 on 01328 850555.  Alternatively, email us at: info@p4fastel.co.uk or visit our website at www.p4fastel.co.uk